Up to 16.5 SEER
Up to 9.5 HSPF
As low as 68 dB2
Silencer System II™ 2-stage models, compressor sound blanket 1-stage models
WeatherArmor™ System
Environmentally-sound Puron® refrigerant
Filter drier for reliable operation
10-year parts limited warranty when properly registered
25HCB3
Performance |
Efficiency |
Up to 15.5 SEER; Up to 8.8HSPF |
Limited Warranty |
10-year parts limited warranty when properly registered1 |
ENERGY STAR® |
Details |
All Carrier heat pump products achieving system combinations of 14.5 SEER, 8.2 HSPF and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Heat pumps must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit ENERGY STARwebsite. |
Sound |
Quiet Level2 |
As low as 70 dB |
Features |
Sound suppressing compressor blanket |
Controls |
Controls Supported |
Edge® and Comfort™thermostats |
Diagnostic Intelligence |
Nominal |
Technology |
Refrigerant |
Environmentally-soundPuron® refrigerant |
Compressor |
Single-stage Scroll |
Heating Capacity (Btuh) |
18,000 - 60,000 |
Cooling Capacity (tons) |
1.5 - 5 |
Aesthetics |
Construction |
Galvanized steel |
Paint |
Baked-on, powder coat paint |
Protection |
WeatherArmor™ |
Coil Guard |
Steel, louver coil guard |
|
25HCB6
Performance |
Efficiency |
Up to 16.5 SEER; Up to 9.5HSPF |
Limited Warranty |
10-year parts limited warranty when properly registered1 |
ENERGY STAR® |
Details |
All Carrier heat pump products achieving system combinations of 14.5 SEER, 8.2 HSPF and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Heat pumps must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit ENERGY STARwebsite. |
Sound |
Quiet Level2 |
As low as 70 dB |
Features |
Sound suppressing compressor blanket |
Controls |
Controls Supported |
Edge® and Comfort™ 2-stage thermostats |
Diagnostic Intelligence |
Nominal |
Technology |
Refrigerant |
Environmentally-soundPuron® refrigerant |
Compressor |
Two-stage Scroll |
Heating Capacity (Btuh) |
24,000 - 60,000 |
Cooling Capacity (tons) |
2 - 5 |
Aesthetics |
Construction |
Galvanized steel |
Paint |
Baked-on, powder coat paint |
Protection |
WeatherArmor™ |
Coil Guard |
Steel, louver coil guard |
|
25HCC5
Performance |
Efficiency |
Up to 16 SEER; Up to 9HSPF |
Limited Warranty |
10-year parts limited warranty when properly registered1 |
ENERGY STAR® |
Details |
All Carrier heat pump products achieving system combinations of 14.5 SEER, 8.2 HSPF and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Heat pumps must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit ENERGY STARwebsite. |
Sound |
Quiet Level2 |
As low as 68 dB |
Features |
Sound suppressing compressor blanket |
Controls |
Controls Supported |
Edge® and Comfort™thermostats |
Diagnostic Intelligence |
Nominal |
Technology |
Refrigerant |
Environmentally-soundPuron® refrigerant |
Compressor |
Single-stage Scroll |
Heating Capacity (Btuh) |
18,000 - 60,000 |
Cooling Capacity (tons) |
1.5 - 5 |
Aesthetics |
Construction |
Galvanized steel |
Paint |
Baked-on, powder coat paint |
Protection |
WeatherArmor™ |
Coil Guard |
Steel, louver coil guard |
|
25HPA5
Performance |
Efficiency |
Up to 16.5 SEER; Up to 9.3HSPF |
Limited Warranty |
10-year parts limited warranty when properly registered1 |
ENERGY STAR® |
Details |
All Carrier heat pump products achieving system combinations of 14.5 SEER, 8.2 HSPF and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Heat pumps must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit ENERGY STARwebsite. |
Sound |
Quiet Level2 |
As low as 68 dB |
Features |
Silencer System II |
Controls |
Controls Supported |
Infinity® control, Edge® andComfort™ thermostats |
Diagnostic Intelligence |
Enhanced diagnostics with Infinity control |
Technology |
Refrigerant |
Environmentally-soundPuron® refrigerant |
Compressor |
Single-stage Scroll |
Heating Capacity (Btuh) |
18,000 - 60,000 |
Cooling Capacity (tons) |
1.5 - 5 |
Aesthetics |
Construction |
Galvanized steel |
Paint |
Baked-on, powder coat paint |
Protection |
WeatherArmor™ |
Coil Guard |
Steel, louver coil guard |
↑ Back to Top |
25HPA6
Performance |
Efficiency |
Up to 17 SEER; Up to 9.7HSPF |
Limited Warranty |
10-year parts limited warranty when properly registered1 |
ENERGY STAR® |
Details |
All Carrier heat pump products achieving system combinations of 14.5 SEER, 8.2 HSPF and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Heat pumps must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit ENERGY STARwebsite. |
Sound |
Quiet Level2 |
As low as 69 dB |
Features |
Silencer System II |
Controls |
Controls Supported |
Infinity® control, Edge® andComfort™ 2-stagethermostats |
Diagnostic Intelligence |
Enhanced diagnostics with Infinity control |
Technology |
Refrigerant |
Environmentally-soundPuron® refrigerant |
Compressor |
Two-stage Scroll |
Heating Capacity (Btuh) |
24,000 - 60,000 |
Cooling Capacity (tons) |
2 - 5 |
Aesthetics |
Construction |
Galvanized steel |
Paint |
Baked-on, powder coat paint |
Protection |
WeatherArmor™ |
Coil Guard |
Steel, louver coil guard |
|
|